Verification of colilert methodology for determining and quantifying total coliforms and escherichia coli in a natural water matrix

Authors

  • C. M. Arboleda-Baena
  • L. M. Arismendi-González
  • M. Sepúlveda-Sánchez
  • M. Rodríguez-López
  • J. Betancur-Urán

Keywords:

Colilert methodology, microbial water quality indicators, most probable number

Abstract

Due to its selectivity and specificity, the Colilert methodology allows one to detect the sanitation indicators of water quality, total Coliforms and Escherichia coli. The aim of this study was to test the Colilert methodology applied to a natural water matrix. With a variation coefficient (CV) less than 6% and 7% for total Coliforms and E. coli respectively, this methodology has proven its repeatability. For both indicators, the middle accuracy was CV < 6% and percentages of recuperation were between 80–120%. The results proved that this method is precise, repeatable and accurate, according to the acceptance criteria entered in the Colombian Technique Guide GTC 84 from 2003; the Standard methods for the examination of water and the International Rule ISO/9308–2:2012. Thus, the method is suitable for detecting and quantifying total Coliforms and E. coli, while providing truthful and timely results for customers.

Article Metrics

|Abstract: 4275 | HTML (Español (España)): 708 | PDF (Español (España)): 2438 |

Author Biographies

C. M. Arboleda-Baena

Grupo de Investigación en Gestión y Modelación Ambiental, GAIA. microbiología.gaia@gmail.com

L. M. Arismendi-González

Grupo de Investigación en Gestión y Modelación Ambiental, GAIA. microbiología.gaia@gmail.com

M. Sepúlveda-Sánchez

Grupo de Investigación en Gestión y Modelación Ambiental, GAIA. microbiología.gaia@gmail.com

M. Rodríguez-López

Grupo de Investigación en Gestión y Modelación Ambiental, GAIA. microbiología.gaia@gmail.com

J. Betancur-Urán

Grupo de Investigación en Gestión y Modelación Ambiental, GAIA. microbiología.gaia@gmail.com

References

. Organización Mundial de la Salud, OMS. Agua. Nota descriptiva Nº391, Centro de Prensa, 2014 Disponible en : http://www.who.int/mediacentre/factsheets/fs391/es/ [Consultada el 1 de Septiembre de 2015]

. Organización Mundial de la Salud, OMS. Guidelines for safe recreational water environments Volume 1: Coastal and fresh waters, Chapter 4 Faecal pollution and water quality, 2003.

. Organización Mundial de la Salud, OMS. Enfermedades diarréicas. Nota descriptiva Nº 330, Centro de Prensa, 2013. Disponible en: http://www.who.int/mediacentre/factsheets/fs330/es/ [Consultado el 5 de Septiembre de 2015]

. IDEXX. Validación del método Colilert®-18/Quanti-Tray® para el recuento de E. coli y de bacterias coliformes en muestras de agua, One IDEXX Drive, Westbrook, Maine 04092, EE. UU, 2008.

. García, G., Velásquez, L.F., Gómez, G., Pineda, F. y Saldarriaga, Y. Manual de laboratorio de microbiología general. Universidad de Antioquia, Facultad de Ciencias Exactas y Naturales. Instituto de Biología, Medellín, 2004.

. República de Colombia. Usos del agua y residuos líquidos. República de Colombia. Decreto 1594 de 1984. Bogotá. 1984.

. Norma técnica Colombiana. Requisitos generales para la competencia de los laboratorios de ensayo y calibración, NTC-ISO/IEC 17025, ICONTEC, Ed 2005.

. República de Colombia. Normas técnicas de calidad del agua potable, Decreto 475 de 1998, Bogotá, 1998.

. International Standards Organization, ISO. Calidad del Agua- Enumeración de Escherichia coli y bacterias Coliformes- Parte 2: Método del número más probable, NORMA ISO/9308-2, 2012.

. Instituto Colombiano de Normas Técnicas y Certificación, ICONTEC. Esterilización de productos para el cuidado de la salud. Requisitos para validación y rutina de control, Esterilización por calor húmedo industrial, Norma técnica Colombiana NTC 4543, Bogotá, D.C, 1998.

. International Standards Organization, ISO. Provides guidance on planning water sampling regimes, on sampling procedures for microbiological analysis and on transport, handling and storage of samples until analysis begins, ISO 19458:2006 focuses on sampling for microbiological investigations, ISO 19458, 2006.

. Guidance on Validation of Microbiological Methods. Calidad del agua, Guía para la orientación acerca de la validación de métodos de análisis microbiológicos, Adopción idéntica (IDT) por traducción de la ISO/TR 13843:2000 Water Quality, GTC 84, 2003.

. American Public Health Association. Standard methods for the examination of water and wastewater. 9223, Enzyme Substrate Coliform Test, Vol 2, 22ND Edition, Washington DC, 2012.

. American Public Health Association. Standard methods for the examination of water and wastewater, 9221 C, Estimation of Bacterial Density, Vol 2, 22ND Edition, Washington DC, 2012.

. Roa-Navarro, M.O., Orjuela L.C y Solano-Duque, M.E. Determinación de Coliformes totales y E. Coli de aguas mediante la técnica de sustrato definido, colilert por el método de Numero Más Probable. Instituto de Hidrología, Meteorología y Estudios Ambientales, Ministerio de Ambiente, Vivienda y Desarrollo Territorial, República de Colombia, Subdirección de hidrología, Grupo laboratorio de Calidad Ambiental, Código TP0423, Versión 02, 2007.

. Mathieu, N. Quality Assurance Project Plan, Fecal Coliform Method Comparison Study in Estuarine Waters of Washington State, Washington State Department of Ecology, 2012.

. Bohn, G y Brouillard, E. Alternative Bacteria Source Identification using Colilert®/Quanti-Tray 2000 Test Method in Irrigated Agricultural Watersheds, Washington State Department of Ecology, 2011.

Published

2016-06-30

How to Cite

Arboleda-Baena, C. M., Arismendi-González, L. M., Sepúlveda-Sánchez, M., Rodríguez-López, M., & Betancur-Urán, J. (2016). Verification of colilert methodology for determining and quantifying total coliforms and escherichia coli in a natural water matrix. Revista Politécnica, 12(22), 105–112. Retrieved from https://revistas.elpoli.edu.co/index.php/pol/article/view/882

Issue

Section

Articles